BlkType
(NV Parameter, Integer) i85
Range
0, 1, 2, 4, 5 or 8
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets its value to that selected by the user.
Purpose
BlkType
specifies configuration as a position, velocity, or torque
block.
Guidelines
BlkType
sets the overall control functionality of the drive. For
block diagrams of the drive configurations, refer to the manual which
describes the alternative
BlkType
settings. When used in any of the
analog modes, the analog control is the differential voltage applied to
the Analog Cmd+ and Analog Cmd- inputs (J4-1 and J4-2
respectively).
BlkType
Servo Configuration
0
Analog Torque Block
1
Analog Velocity Block
2
Digital Position Block
4
EncFreq Torque Block
5
EncFreq Velocity Block
8
Serial Port Command
Velocity block
If
Position Block Input Select
is mapped to a BDIO
input and the input is asserted, then the active Block Type will be
Position Block (
BlkType
= 8). If the input is not asserted, then the
active Block Type is controlled by
BlkType
.
7 - 24