5 Setting Parameters for
Electronic Gearing
Introduction
This chapter provides procedures for setting up the SC900 for use
as either as an electronic gearing slave with a master reference
encoder or for use with a stepper indexer that generates step and
direction signals.
Both electronic gearing and stepper emulation modes are based
on configuring the SC900 with a position loop, setting the
command scale factor via the
PulsesIn, PulsesOut,
PulsesFOut
parameters, and selecting the proper command
pulse stream encoding format. Figure 3 in Appendix C shows the
command scaling and position loop block diagram.
The setup for either mode of operation is very straightforward
using the New Setup selection from the File menu or the Drive
Setup selection from the Drive menu.
5.1 Slaving the SC900 to a Master Encoder
The following procedure describes how to use 930 Dialogue to
easily set up your SC900 for use as an Electronic Gearing Slave
with a Master Reference encoder.
Procedure
1. Select New Setup from the Files menu.
2. Select Automatic for the Set Up Mode.
3. Enter your motor part number and press <Enter>.
4. Select your drive model number.
5. Select the type of line voltage, if applicable.
6. Select Position Block-Electronic Gearing on the Mode of
Operation screen.
MA930 Manual
5 - 1