PulsesOut
(NV Parameter, Integer) i59
Units
Resolver counts
Range
-32,768 to +32,767
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets its value to 1.
Purpose
PulsesOut
specifies the number of resolver counts the motor will
move for each
PulsesIn
number of
EncPos
command counts.
Integral part of numerator of the exact electronic gearing ratio.
Guidelines
PosCommand
(New) =
PosCommand
(Old) +
Ratio*(EncPos
(
New
) -
EncPos
(
Old
))
Ratio =
PulsesOut
PulsesFOut
PulsesIn
+
−
(
*
)
2
16
calculated once per position loop update period.
MA930 Manual
7 - 101