BDIOMapx
(NV Parameter, Integer) i270-i275
Range
-2,147,483,648 to 2,147,483,648
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets their values as follows:
BDIOMap1
Fault Reset Input Active Low
BDIOMap2
CW Inhibit Input Active Low
BDIOMap3
CCW Inhibit Input Active Low
BDIOMap4
OFF
BDIOMap5
Brake Output Active High
BDIOMap6
Fault Output Active High
Purpose
Sets the logical function of the BDIOs on J4-7 to J4-12.
Guidelines
Although the value is a 32 bit integer, the value is easily set in the
Variables Screen or the Parameter Form by menu pick. First select
Off, Input, or Output, then pick a function, and finally select the logic
polarity as active high or low.
Input
Functions
FaultReset, RunStop, Enable2, VelCmdSrc, CwInh,
CcwInh, AInNull, Position Block, Use CmdGain2
Output
Functions
Fault, Enabled, Brake, ElecRev, MechRev, Zero
Speed, PosError Warning