Kvp
(NV Parameter, Float) f15
Units
Amperes/(Radians/Second)
Range
0 to Ipeak * 12.6
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up calculates its value based on the selected velocity
loop bandwidth.
Purpose
Kvp
sets the proportional gain of the velocity loop.
Guidelines
Kvp
is defined by the following relationship:
Kvp
= Commanded motor torque current / Velocity Error;
where Commanded motor torque current has units of (amperes), and
Velocity Error has units of (radians/second).
Kvp
must be adjusted for total load inertia and motor torque constant
as described in Chapter 6.
Note:
Idealized velocity loop bandwidth (in Rad/sec) equals
Kvp * Kt / J, where J is the total shaft inertia and K
t
/J units are
rad/sec
2
/A . Maximum recommended idealized bandwidth is 2
π
*400
Rad/sec.
7 - 82
MA930 Manual