CmdGain
(NV Parameter, Float) f22
Units,
Range
BlkType
= 0 Amperes/Volt
±
10
10
* I
peak
BlkType
= 1 KRPM/Volt
±
10
10
BlkType
= 2 Not Applicable
(see
PulsesIn
,
PulsesOut
)
BlkType
= 4 Amperes/KHz
±
10
8
* I
peak
BlkType
= 5 KRPM/KHz
±
10
7
BlkType
= 8 Not Applicable
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up calculates its value based on the selected motor and
drive.
Purpose
CmdGain
sets the scale factor of the analog input.
Guidelines
CmdGain
is a floating point variable that sets the command gain of
the analog input (voltage from J4-1 to J4-2) for
BlkType’s
0
(Analog torque block), and 1 (Analog velocity block) and the encoder
input frequency for
BlkType’s
4 (EncFreq Torque) and 5
(EncFreq Velocity).
If
Use CmdGain2
is mapped to a BDIO Input and the input is
asserted, then the active value for Command Gain will be
CmdGain2
.
If the input is not asserted, then the active value for Command Gain
will be
CmdGain
.
7 - 30
MA930 Manual
Содержание OC930
Страница 38: ...Page empty ...
Страница 44: ...Page empty ...
Страница 56: ...Page empty ...
Страница 184: ...Page empty ...
Страница 188: ...Page empty ...