CcwInh
(Mappable Input Function, Variable, Integer) i164
Range
0 or 1 (0 is normal operation; 1 is function activated)
Default
0 at power up if not mapped
Purpose
CcwInh
selects between normal operation and clamping
VelCmdA
to
be only positive.
Guidelines
When
CcwInh
= 1, counter-clockwise rotation is inhibited. That is,
VelCmdA
is clamped to be only positive. For positioning
BlkType,
PosError
must return to near 0 or be positive to exit this mode.
When
CcwInh
and
CwInh
are both active
VelCmdA
is set to 0 and
the first inhibit to go inactive stops that inhibit immediately
independent of
BlkType
.
While actively inhibiting CCW motion, the status LED alternates
8
.
With Both CCW and CwInh active, the LED alternates
8
.
7 - 28