DecelLmt
(NV Parameter, Float) f277
Units
RPM/sec
Range
0 to 1 x 109
Default
Parameter value set before last NVSAVE. 930 Dialogue New Set Up
or Drive Set Up sets it value to 0 (no deceleration limiting).
Purpose
Slew rate limit on actual velocity command magnitude decreases. See
VelCmdA
for the
VelCmd
value after slew limiting.
Guidelines
Setting
DecelLmt
to 0 turns off
DecelLmt
slew limiting;
VelCmdA
can immediately decrease to equal
VelCmd
. See
AccelLmt
for control of
VelCmdA
magnitude increases.
For position loops, setting either
AccelLmt
or
DecelLmt
to a value
is not recommended as it may cause excessive overshoot.
7 - 36
MA930 Manual