ILmtMinus
(NV Parameter, Integer) i4
Units
% (Percentage) of peak current rating of drive
Range
0 to 100
Default
The default value, for New Set Up and Drive Set Up menu picks, is
based upon the selected motor and drive.
Purpose
ILmtMinus
(Counter-Clockwise Current Limit) sets the maximum
allowable torque current amplitude in the counter-clockwise direction.
This is a percentage of the drive’s peak current rating (
Ipeak
).
Guidelines
Only integer values may be entered (i.e. no fractional numbers).
Warning
If ILmtMinus*0.01*Ipeak > twice the motor’s continuous
current rating, the motor’s over temperature sensor is not
guaranteed to always respond fast enough to prevent motor
winding damage.
7 - 66