E-023-2-E
Status Type
Name
Details
Resolution Conditions
Fixed
Output
Analog Output 1 Fixed
Executing analog output 1 fixed output
When analog output 1 fixed output
ends
Analog Output 2 Fixed
Executing analog output 2 fixed output
When analog output 2 fixed output
ends
Pulse Output 1 Fixed
Executing pulse output 1 fixed output
When pulse output 1 fixed output
ends
Pulse Output 2 Fixed
Executing pulse output 2 fixed output
When pulse output 2 fixed output
ends
Status Output Fixed
Executing status output fixed output
When status output fixed output ends
0% Signal Lock
Executing 0% Signal Lock from status
input
When 0% Signal Lock from status
input ends
Calibration
in Progress
Calibration in Progress
Executing Auto Zero
When Auto Zero ends
H/L Alarm
H/L Alarm Triggered
・
H/L Alarm set for Status Output
func
・
High Alarm or H/L Alarm set for H/L
Alarm type, and the measurement
value set for H/L Alarm Assign is
High Alarm point or higher
・
Low Alarm or H/L Alarm set for H/L
Alarm type, and the measurement
value set for H/L Alarm Assign is
Low Alarm point or lower
H/L Alarm occurs when any of the
conditions described above are met
・
When something other than H/L
Alarm is set for Status Output func
・
If High Alarm or H/L Alarm is
set for H/L Alarm type, and the
measurement value set for H/L
Alarm Assign is High Alarm point -
H/L Alarm hys or lower
・
If Low Alarm or H/L Alarm is
set for H/L Alarm type, and the
measurement value set for H/L
Alarm Assign is Low Alarm point +
H/L Alarm hys or higher
The alarm is cleared when the
above conditions are met
Maintenance
Self Diagnosis
Conducting self-diagnosis
Self Diag - Hardware
Self Diag - Drive coil check
Self Diag - Xmtr condition
Self Diag - LCD test
When the diagnosis type in the above
list ends
Installation
Executing installation
Installation - Static
Installation - Dynamic
When the installation type in the
above list ends
Xmtr
Operation
Xmtr Operating
-
Time Over
Maximum operating time exceeded
(operating time is in excess of 100,000
hours)
When the master reset is executed
Xmtr Warm Up
Converter warming up (when power is
turned on)
When 20 minutes passes after power
is turned on
Power OK?
(When the previous time between power
on and off is under three seconds, ten
times in a row)
When 20 minutes passes after the
last time power is turned on
Status List
Item
Product Code
Description
① ② ③ ④ ⑤ ⑥ - ⑦ ⑧ ⑨ ⑩ ⑪ ⑫
Mode
E L 2 3 1 0
-
Smart Communication Unit
Power source
0
Always "0"
Applicable flowmeter
(application software)
8
OVAL Coriolis Flowmeter ALTImass
(PA0K Transmitter)
Language
0
Less application software ("0" in the 8th digit)
J
Japanese
(Japanese version OS)
E
English
(English version OS)
Interface
0
Less interface (application software only)
1
Interface provided
Media
(application software)
0
Less application software ("0" in the 8th digit)
1
CD
-
ROM
9
Other than the above
Reserve code
0