2. Install the Antenna.
a. Loosen and remove the hole plug wing-nut and washer from the inside of the enclosure.
b. Remove the hole plug assembly from the knockout on the top of the enclosure.
c. Carefully punch out the knockout.
IMPORTANT:
Make sure the knockout is punched out clean and that the top of the enclosure
around the hole does not get bent.
d. Put the bulkhead connector and cable of the antenna assembly through the hole.
NOTE:
If the connector does not go through the hole easily, use a file to increase the
dimension of the hole sufficient for clearance. Be sure to clean the filings from the bottom of
the enclosure.
e. Put the washer and nut of the antenna assembly on the threaded bulkhead connector. Turn
the nut clockwise until it is tight.
f. Attach the coaxial cable connector of the antenna to the Cellular connector of the Cellular
Modem.