Inbound Connection: FSC3000 and Cellular Modem
NOTE:
The colors of the cables in the illustration are used to show the routing of the wires
only.
1. P/N 20-1519-01-018:
l
Connect the
DB9 Male connector end
to the
RS232 Port
of the Cellular Modem.
l
Connect one end of the
CAT5e Patch Cable
to the RJ45 socket side of the Connector and the
other end to the FSC3000 RS232 Port #1.
INFORMATION:
The illustration above shows the ports as they are seen from the top of
the FSC3000. Port 1 is the one on the right of the back row of RS-232 ports.
2. Antenna P/N 75-2064: Make sure the Antenna is connected to the
Cellular
coaxial connector on the
Cellular Modem (see step 2f of the Antenna installation instructions above).
3. P/N 20-1742:
l
Connect the 4-Pin clip connector plug to the DC Power socket of the Cellular Modem.
l
Connect the white Molex terminal end to an open connector on the PetroNet Power Hub Board (J6 /
J7 / J8).
Outbound Connection: FSC3000 and IP Gateway (Optional)
NOTE:
One (1) 20-6000 IP Gateway can be installed internally to the PV200. In this scenario,
the IP Gateway Ethernet connection comes from the Cellular Modem.
4. P/N 20-1517-01:
l
Connect the DB25 end of the cable to the POS Serial Port 1 of the IP Gateway.
l
Connect the RJ45 end of the cable to the FSC3000 RS232 Port #5.
INFORMATION:
The illustration above shows the ports as they are seen from the top of
the FSC3000. Port 5 is the one on the right of the front row of RS-232 ports.
5. CAT5 cable (not supplied):
l
Connect one end of the cable to the Ethernet port of the IP Gateway.
l
Connect the other end of the cable to the Cellular Modem Ethernet port.
6. 20-0418 Power Converter (this must be ordered separately):
l
Connect the barrel end plug of the cable to the Power jack of the IP Gateway. Push the end into the
socket and turn 90° clockwise to lock the plug.
l
Connect the white Molex terminal end to an open connector on the PetroNet Power Hub Board (J6 /
J7 / J8).
Doc. No.: M1010 Rev.: 10
Page 84 of 98
Содержание Petro Vend 200 M1010
Страница 16: ...Typical System Diagram with an Integrated FSC Electronic Pump Control Doc No M1010 Rev 10 Page 16 of 98...
Страница 34: ...Section 8 Antenna Installation Doc No M1010 Rev 10 Page 34 of 98...
Страница 36: ...Section 9 Main Board 9 1 Main Board Connections Doc No M1010 Rev 10 Page 36 of 98...
Страница 43: ...11 2 PV200 Display Doc No M1010 Rev 10 Page 43 of 98...
Страница 44: ...11 3 PV200 Pocket Doc No M1010 Rev 10 Page 44 of 98...
Страница 85: ...FSC3000 Internal Connections Inbound Outbound with IP Gateway Only Doc No M1010 Rev 10 Page 85 of 98...
Страница 96: ...Web links updated 2 13 2019 to new www opwglobal opw fms site Doc No M1010 Rev 10 Page 96 of 98...
Страница 98: ......