15.3.2 Comdata (Terminal Fuel network, dial-up only)
The Comdata (terminal fuel) host should only be purchased when you are a private site that dispenses fuel to
its own employees (or at least to a controlled group of Comdata fleet customers, not open to the public). Card
prompting is specific to Fleet table account based setup.
When is selected there is an option 12 specific to its setup:
NETWORK option settings
NETWORK : Comdata
1 - Site/Terminal ID...............
2 - Site Name......................
3 - Site City......................
4 - Site State.....................
5 - Redial Attempts................ 1
6 - Connect Time......(Seconds).... 30
7 - Local Authorization............ Disabled
8 - Network System................. ON
ON............................. 12:00 AM
OFF............................ 12:00 AM
9 - Authorization Message.......... ^0^FHAVE A SAFE TRIP
10 - Re-Prompt Time....(Minutes).... 10 (set to zero for DTC systems)
11 - Communication Parameters....... 2400 7E1 T60Y
12 - Process USA Market MC? ........ NO
Process Canadian Market MC? ... NO
Enter option number or press [RETURN] to exit:
1-4. Setup Options 1-4
Options 1- 4 should be set up with information from the network. The Technician should contact the Merchant
for information.
5. Redial Attempts
The Redial Attempts option defines how many times the system will try to connect to the network. Default is 1.
6. Connect Time
The Connect Time option defines the maximum time to stay connected to the network when trying to approve
a card. If this time is reached, the transaction will be terminated.
7. Local Authorization
The Local Authorization option allows configuration of processing rules if the FSC can authorize network
cards offline down the host is down. Not all networks support this feature. If you enable Local Authorization
for a specific host you should first confirm with the host that this feature is allowed for the specific site.
NOTE:
Depending on the host being configured different options may be presented.
Enter option number or press [RETURN] to exit: 7
Enable LOCAL AUTHORIZATION? (Y/N) : y
Enter NUMBER of Auth allowed (default = 1) : 15
ß
number of auth’s allowed
Enter DURATION in Mins. (default = 1) : 30
ß
number of minutes allowed
Allow KEYED Cards? (Y/N): N
ß
allowing keyed card numbers can increase risk
Doc. No.: M00-051.00 Rev.: 10
Page 106 of 181
Содержание M00-051.00 FSC3000
Страница 60: ...Doc No M00 051 00 Rev 10 Page 60 of 181...
Страница 63: ...Doc No M00 051 00 Rev 10 Page 63 of 181...
Страница 69: ...Doc No M00 051 00 Rev 10 Page 69 of 181...
Страница 99: ...Doc No M00 051 00 Rev 10 Page 99 of 181...
Страница 105: ...CFN Product Codes Code Description 96 WASHROOM FACILITIES 97 LODGING Doc No M00 051 00 Rev 10 Page 105 of 181...
Страница 129: ...Petrol Training Screens Doc No M00 051 00 Rev 10 Page 129 of 181...
Страница 130: ...CNG Training Screens Doc No M00 051 00 Rev 10 Page 130 of 181...
Страница 133: ...034 ULS Premium Diesel 010 Bio Diesel2 011 Bio Diesel5 012 Bio Diesel10 Doc No M00 051 00 Rev 10 Page 133 of 181...
Страница 181: ......