The Partial Access password will be limited to these select commands:
Show - System, Version, Flags, PCT x, FIT x, VIT x, Transaction CF
Install Pump x (clear pump sentry)
Set Fueltype (change product prices
PCF Automated management commands - Card backup/restore/update
Passthru
2.1.3 User Access
The system supports up to five (5) defined users that have access to all commands except “SET ADMIN, SET
NETWORK, or SET FLEET.” Individual users can be set up to see bank card ISO numbers (first six (6) digits)
in the transactions when performing “SHOW TRANSACTION” commands. Users can also be limited to the
number of days of system access. To access the system using a User password, type “LOGIN” <user name>.
A prompt for the User’s password will be displayed. Once the User password is entered, the user prompt
“(User Name)>” will be displayed.
2.1.4 Admin Access
The
Admin
is the predefined user who has access to every command. It is recommended that the Admin
account only be used if the “SET ADMIN, SET NETWORK, or SET FLEET” commands are needed.
The
Admin account is limited in access to the system through only a Direct or Dial-in connection.
A User account is needed to access the FSC3000
™
system if a TCP/IP connection is in use
.
The
Admin
password should be stored in a safe location. Once the
Admin
password is entered, the
prompt “Admin>” will be displayed.
2.2 Set Admin (Admin Login Required)
The
Set Admin
command allows for the management of the supported five (5) additional users of the
system, and clears the system log. This command will not be available when connected using Ethernet.
Once theFSC3000
™
system is started, only the Admin will be able to access this command.
Type:
Set Admin <ENTER>
Administrator Menu
1. Create User (free:x)
2. Delete User
3. Show User(s)
4. Change Password(s)
5. Clear Event Log
Select Administrator option or press [ENTER] to exit:
2.2.1 Create User
The
Create User
option allows up to five (5) other users of the system. Each user can be set up to either see
or not see bankcard ISOs and can be configured to define a time limit (in days) to system access.
Enter a new (case sensitive) USER name: Tech (maximum 10 characters)
Passwords MUST be a minimum length of eight (8) characters (max 15), contain at
least one numeric digit, one lower-case character and one upper-case
character.Special characters are optional.
Enter Password for Tech: *******
Re-enter to confirm password: *******
When viewing transactions can this user see a bankcard's ISO (Y/N)? Y
Is this a time limited User (Y/N)? y
Doc. No.: M00-051.00 Rev.: 10
Page 19 of 181
Содержание M00-051.00 FSC3000
Страница 60: ...Doc No M00 051 00 Rev 10 Page 60 of 181...
Страница 63: ...Doc No M00 051 00 Rev 10 Page 63 of 181...
Страница 69: ...Doc No M00 051 00 Rev 10 Page 69 of 181...
Страница 99: ...Doc No M00 051 00 Rev 10 Page 99 of 181...
Страница 105: ...CFN Product Codes Code Description 96 WASHROOM FACILITIES 97 LODGING Doc No M00 051 00 Rev 10 Page 105 of 181...
Страница 129: ...Petrol Training Screens Doc No M00 051 00 Rev 10 Page 129 of 181...
Страница 130: ...CNG Training Screens Doc No M00 051 00 Rev 10 Page 130 of 181...
Страница 133: ...034 ULS Premium Diesel 010 Bio Diesel2 011 Bio Diesel5 012 Bio Diesel10 Doc No M00 051 00 Rev 10 Page 133 of 181...
Страница 181: ......