16.6.2 Termination Codes (upper-case letter) – Authorization Granted
Code
Description
Cause
Possible Solution
C
Pump error,
premature
busy
D
Pump error -
Reset
Quantity
exQceeded
1 unit of Pulse(s) being received by
the pump controller without sensing the
pump is on
PCT - Handle or Current sense PCM -
Handle or Voltage sense
K800 Hybrid - Current sense
Verify pump controller is
set up for the correct
sensing method
Verify pump wiring is
correct
E
No 'Pump
Handle busy'
Pump controller never sensed the pump
on and the handle timer was reached.
Verify pump controller is
set up for the correct
sensing method
Verify pump wiring is
correct
F
No fueling
pulses
Pump controller sensed pump on, pulses
where never received and the first
pulse timer was reached.
Verify pulser is working
Verify pulser wiring
G
Pump
currently
active
I
Normal
Transaction terminated normally
J
Quantity
limit
exceeded
One of the Quantity limits for the
transaction has been reached
Verify pump, card/account
record quantity limits
are adequate and adjust
accordingly
K
Total
transaction
timeout
exceeded
The total transaction fueling timer has
been reached
Verify total transaction
fueling time is adequate
for the pump and adjust
accordingly
L
Pulser error
Only on flow switch applications
Pulses not being received within 5
seconds after the flow switch
activation
Verify pulser is working
Verify pulser wiring
Verify flow switch is not
bad
M
Emergency
stop
Emergency stop switch pressed on the
System2 FIT or K800 Hybrid terminal (if
equipped)
Verify Emergency switches
are not shorted
N
Missing pulse
detected
Pump controller sensed pump on, pulses
where received, then pulses stopped
being received and the Missing pulse
timer was reached.
Doc. No.: M00-051.00 Rev.: 10
Page 163 of 181
Содержание M00-051.00 FSC3000
Страница 60: ...Doc No M00 051 00 Rev 10 Page 60 of 181...
Страница 63: ...Doc No M00 051 00 Rev 10 Page 63 of 181...
Страница 69: ...Doc No M00 051 00 Rev 10 Page 69 of 181...
Страница 99: ...Doc No M00 051 00 Rev 10 Page 99 of 181...
Страница 105: ...CFN Product Codes Code Description 96 WASHROOM FACILITIES 97 LODGING Doc No M00 051 00 Rev 10 Page 105 of 181...
Страница 129: ...Petrol Training Screens Doc No M00 051 00 Rev 10 Page 129 of 181...
Страница 130: ...CNG Training Screens Doc No M00 051 00 Rev 10 Page 130 of 181...
Страница 133: ...034 ULS Premium Diesel 010 Bio Diesel2 011 Bio Diesel5 012 Bio Diesel10 Doc No M00 051 00 Rev 10 Page 133 of 181...
Страница 181: ......