
7-52
Para
meter
No.
Page
Control mode
Chan-
ges
during
opera-
tion
De-
fault
setting
Set-
ting
range
Description
Name
Para
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
con-
trol
Chan-
ges
during
opera-
tion
De-
fault
setting
Set-
ting
range
Description
Display
name
o1-02
Monitor
selection
after
power-on
Sets the monitor item to be
displayed when the power is
turned on.
1:
Frequency reference
2:
Output frequency
1 to 4
1
OK
B
B
B
B
6-111
Power-On
Monitor
2:
Out ut frequency
3:
Output current
4:
The monitor item set for
o1-01
o1-03
Frequency
reference
setting and
display
units
Sets the units that will be set
and displayed for the
frequency reference and
frequency monitor.
0:
0.01-Hz units
1:
0.01% units (Maximum
frequency is 100%)
2 to 39: r/min units (Sets the
motor poles. Cannot
be set in Flex Vector
Control.)
40 to 39999: User desired
display
Set the desired values for
setting and
display for the
max. frequency.
0 to
39999
0
NO
B
B
B
B
5-9
Display
Scaling
max. frequency.
Example: When the max. fre-
quency value is 200.0, set
12000
Set four digits
without the dec-
imal point
Set the position
of the decimal
point in the first
digit.
o1-04
V/f pattern
setting
units
Set the V/f pattern setting units.
(E1-04, 06, 09 set units)
0:
Hz units
1:
r/min units
0, 1
0
NO
X
X
X
B
6-31
Display
Units
1:
r/min units
Note: Effective only in the flux
control vector mode.
o1-05
Not used
Do not set.
---
0
---
---
---
---
---
---
o 05
Address
Display
o o se
0
H
Key Selections: o2
Para
meter
Name
Description
Setting
range
Default
setting
Chan-
ges
Control mode
Page
meter
No.
Display
name
range
setting
ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
o2-01
Local/Re-
mote Key
Sets the Digital Operator
Local/Remote Key
enabled/disabled.
0:
Disabled
0, 1
1
NO
B
B
B
B
6-112
Local/Re-
mote Key
0:
Disabled
1:
Enabled (Switches between
the Digital Operator and the
parameter settings.)
Parameter Lists
Chapter 7
Содержание SYSDRIVE 3G3FV
Страница 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Страница 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Страница 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Страница 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Страница 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Страница 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Страница 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...