7-29
Para
meter
No.
Control mode
Changes
during
opera-
tion
Default
setting
Setting
range
Description
Name
Para
meter
No.
Flux vec-
tor
Open
loop
vector
V/f with
PG
V/f
control
Changes
during
opera-
tion
Default
setting
Setting
range
Description
Display
name
E5-03
Motor 2
no-load
current
Sets the motor constants of
motor 2, when used for
two-motor switching
Note 1: Enabled when the mo-
0.00 to
2.90
(see
note 5)
1.20
(see
note 3)
NO
A
A
A
A
No-Load
Current
Note 1: Enabled when the mo-
tor 2 selection function
is set for multi-function
input.
note 5)
E5-04
Motor 2
number of
motor poles
Note 2: Set like E1-04 to E2-06.
Note 3: Changes motors after
Inverter and motor stop.
2 to 48
4
NO
A
A
A
A
Number of
Poles
Note 4: Waits to change motor
for 20 to 50 ms after
Inverter input.
E5-05
Motor 2
phase-to-
phase re-
sistance
Note 5: Cannot use motor 1
parameters and motor 2
parameters at same
time.
Note 6: Motor selection signal
0.000
to
65.000
9.842
(see
note 3)
NO
A
A
A
A
Term
Resistance
Note 6: Motor selection signal
will be enabled when
the motor 2 selected
function is set for multi-
E5-06
Motor 2
leakage
inductance
function is set for multi
function output.
Note 7: If the control method for
motor 1 is different from
that for motor 2, all oth-
0.0 to
40.0
18.2
(see
note 3)
NO
A
A
A
A
Leak
Inductance
that for motor 2, all oth-
er parameters of motor
2 will be set to default
settings.
Note 1. These voltages are for the 200-V class; Double the voltage for 400-V class Inverters.
Note 2. The default values are restored if the control mode is changed. The defaults for open-loop
control are shown.
Note 3. The default setting depends on the Inverter’s capacity. The default settings shown in the table
are for 200-V class, 0.4 to 1.5 kW Inverters.
Note 4. The setting range is 10% to 200% of the Inverter’s rated output current. (The default settings
shown in the table are for 200-V class, 0.4-kW Inverters.)
Note 5. The setting range is between 0.00 and 0.1 less than the motor’s rated current. (The default
settings shown in the table are for 200-V class, 0.4-kW Inverters.)
7-2-5 Options Parameter Lists
H
PG Option Setup: F1
Para
meter
Name
Description
Setting
range
Default
setting
Chan-
ges
Control mode
Page
meter
No.
Display
name
range
setting
ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
F1-01
Number of
PG pulses
Sets the number of PG (pulse
generator or encoder) pulses.
0 to
60000
1000
NO
X
Q
X
Q
5-29,
5-46
PG
Pulses/Rev
g
)
Note: Sets the number of pulses
per motor revolution.
Parameter Lists
Chapter 7
Содержание SYSDRIVE 3G3FV
Страница 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Страница 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Страница 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Страница 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Страница 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Страница 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Страница 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...