1-7
•
The 3G3FV allows the following three kinds of access levels to be set in order to further simplify pa-
rameter setting. (An access level is a range of parameters that can be set or referenced.)
S
Quick-start:
Sets/reads parameters required for trial operation. [Factory setting]
S
Basic:
Sets/reads parameters that are commonly used.
S
Advanced:
Sets/reads all the parameters that can be used.
•
In general, press the Enter Key to move from an upper to a lower level. This varies somewhat, howev-
er, according to the access level, as shown in the following diagram. For the Quick-start access level,
which has few parameters that can be set, pressing the Enter Key jumps directly to the Parameter
level; whereas for the Advanced access level, which has many, pressing the Enter Key first leads to
the Group level.
Operation mode
Initialize mode
Program mode
b Application
c Tuning
[Mode]
[Group]
[Function]
[Parameter]
Auto-tuning
mode
Modified
constants mode
b1 Sequence
b1-01 Reference source
b1-02 Run source
b1-03 Stopping method
C1-01 Accel Time 1
C1-02 Decel Time 1
C1 Accel/Decel
b2 DC braking
b3 Speed search
b2-01 Zero speed level
b2-02 DC injection braking current
b3-01 Beginning speed search
b3-02 Speed search operation current
MENU
ADVANCED
BASIC
QUICK-START
Introduction
Chapter 1
Содержание SYSDRIVE 3G3FV
Страница 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Страница 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Страница 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Страница 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Страница 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Страница 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Страница 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...