H
Digital Operator
Operation Mode Indicators
Keys
Execute operations such as setting parameters,
monitoring, JOG, and auto-tuning.
Data Display
Two-line LCD that displays data for monitoring,
parameter names, and set values with 16 charac-
ters per line.
DRIVE:
Lit when in operation mode.
FWD:
Lit when there is a forward command input.
REV:
Lit when there is a reverse command input.
SEQ:
Lit when the forward/reverse command from
the control circuit terminal is enabled.
REF:
Lit when the frequency reference from
control circuit terminals 13 and 14 is enabled.
Key
Name
Function
Operation Mode
Selection Key
Switches between Operator and parameter setting (run command and
frequency reference). This key can be enabled or disabled with a
parameter setting (o2-02).
Menu Key
Displays each mode.
Escape Key
Returns to the status before the Enter Key is pressed.
Jog Key
Enables JOG operation when the 3G3FV is in operation with the
Digital Operator.
Forward/Reverse
Rotation Selection Key
Selects the rotation direction of the motor when the 3G3FV is in
operation with the Digital Operator.
Reset/Digit Selection
Key
Selects digits for parameter settings. Also acts as the reset key when
an fault has occurred. (see note)
Increment Key
Selects modes, groups, functions, parameter names, and set values.
This key increases numbers when pressed.
Decrement Key
Selects modes, groups, functions, parameter names, and set values.
This key decreases numbers when pressed.
Enter Key
Enters modes, functions, parameters, and set values after they are
set.
Run Key
Starts the 3G3FV running when the 3G3FV is in operation with the
Digital Operator.
Stop Key
Stops the 3G3FV running. This key can be enabled or disabled with a
parameter setting (o2-02) in operation with the control circuit terminal.
Note For safety reasons, the reset operation will not function when a forward or reverse run command
is being input. Use the reset after turning OFF the run command.
Introduction
Chapter 1
Содержание SYSDRIVE 3G3FV
Страница 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Страница 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Страница 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Страница 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Страница 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Страница 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Страница 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...