7-39
Setting
value
Page
Control mode
Setting
value
Page
Flux
vector
Open loop
Vector
V/f
w/PG
V/f
1B
During baseblock 2 (OFF: During base block)
OK
OK
OK
OK
---
1C
Motor 2 selected (ON: motor 2 selected)
OK
OK
OK
OK
---
1D
Regenerating (ON: Regenerating)
---
---
---
OK
---
1E
Restart enabled (ON: Restart enabled)
OK
OK
OK
OK
6-107
1F
Motor overload (OL1) pre-alarm (ON: 90% or
more of the detection level)
OK
OK
OK
OK
6-92
20
Inverter overheat (OH) pre-alarm (ON:
Temperature is above L8-02)
OK
OK
OK
OK
6-92
30
During torque limit (current limit) (ON: During
torque limit)
---
---
OK
OK
---
31
During speed limit. (ON: During speed limit)
---
---
---
OK
---
33
Zero-servo end (ON: Zero-servo)
---
---
---
OK
6-93
37
During run 2 (ON: Frequency output, OFF: Base
block, DC braking, initialization, operation stop.
OK
OK
OK
OK
6-92
H
Analog Inputs: H3
Para
meter
Name
Description
Setting
range
Default
setting
Chan-
ges
Control mode
Page
meter
No.
Display
name
range
setting
ges
during
opera-
tion
V/f
control
V/f
with
PG
Open
loop
vector
Flux
vector
H3-01
Signal
selection:
terminal 13
(Voltage)
0:
0 to +10 V
1:
0 to
±
10 V
0, 1
0
NO
B
B
B
B
5-5
Term 13
Signal
H3-02
Gain: termi-
nal 13
Sets the frequency when 10 V
is input, as a percentage of the
i
f
0.0 to
1000.0
100.0
OK
B
B
B
B
5-7
Terminal 13
Gain
,
g
maximum frequency.
H3-03
Bias: termi-
nal 13
Sets the frequency when 0 V is
input, as a percentage of the
i
f
–100.0
to
100 0
0.0
OK
B
B
B
B
5-7
Terminal 13
Bias
,
g
maximum frequency.
+100.0
H3-04
Multi-func-
tion analog
input signal
selection:
terminal 16
0:
0 to +10 V
1:
0 to
±
10 V
0, 1
0
NO
B
B
B
B
5-7
Term 16
Signal
H3-05
Selection:
Terminal 16
Select from the functions listed
on the following table. Refer to
6 93
0 to 1F
1F
NO
B
B
B
B
5-7,
6-93
Terminal 16
Sel
g
page 6-93.
H3-06
Gain: termi-
nal 16
Sets the input gain (level) when
terminal 16 is 10 V.
Th
t
t i th f ll
i
0.0 to
1000.0
100.0
OK
B
B
B
B
5-8
Terminal 16
Gain
The contents in the following
table are taken as 100%.
H3-07
Bias: termi-
nal 16
Sets the input gain (level) when
terminal 16 is 0 V.
Th
t
t i th f ll
i
–100.0
to
100 0
0.0
OK
B
B
B
B
5-8
Terminal 16
Bias
The contents in the following
table are taken as 100%.
+100.0
Parameter Lists
Chapter 7
Содержание SYSDRIVE 3G3FV
Страница 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Страница 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Страница 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Страница 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Страница 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Страница 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Страница 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...