7-4
Para
meter
No.
Page
Control mode
Chang
e dur-
ing
opera-
tion
Default
setting
Setting
range
Description
Name
Para
meter
No.
Page
Flux
vector
Open
loop
vector
V/f
with
PG
V/f
control
Chang
e dur-
ing
opera-
tion
Default
setting
Setting
range
Description
Display
name
A1-05
Setting the
Password
Used to set a four digit number
as the password.
Note: This parameter is not usu-
ally displayed. When the
password (A1-04) is dis-
0 to
9999
0
NO
Q
Q
Q
Q
3-22
Select
Password
assword (A1-04) is dis-
played, hold down the Re-
set/Select Key and press
the Menu Key and the
password will be dis-
played.
A2-01
to
A2-32
Setting the
User
Parameter
Used to set the parameter
numbers that can be set/read.
Maximum 32.
Note It is most effective to set
the user setting parame-
ter to 1 in access level
b1-01
to
o2-08
---
NO
A
A
A
A
3-22
User
Param 1 to
32
g
ter to 1 in access level
A1-01. If set in the Pro-
gram mode only, parame-
ters set in access levels
A2-01 to A2-32 may be
set/read.
Parameter Lists
Chapter 7
Содержание SYSDRIVE 3G3FV
Страница 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Страница 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Страница 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Страница 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Страница 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Страница 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Страница 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...