6-7
6-1-6 Startup Torque Compensation
With open-loop vector control, a starting-torque compensation can be input to decrease the torque ref-
erence’s rise time at startup.
This function is effective for equipment in which a starting torque is required, such as machinery with a
high friction load or cranes. Unlike flux vector control, the compensation is input only at startup.
H
Starting-torque Compensation Function
Settings
Parameter
Display name
Setting
Units
Default
Valid access levels
number
p y
g
range
setting
V/f
Control
V/f with
PG
Open Loop
Vector
Flux
Vector
C4-03
F TorqCmp@start
0.0 to 200.0
0.1%
0.0
---
Advanced
---
C4-04
R TorqCmp@start
–200.0 to 0.0 0.1%
0.0
---
Advanced
---
C4-05
TorqCmp Delay T
0 to 200
1 ms
10
---
Advanced
---
These parameters cannot be changed during operation.
Timing Chart
Note
The Inverter’s torque reference value is at its lower limit
with the torque compensation value shown above.
Frequency reference
Run command
Torque compensation value
Time constant: C4-02
C4-03 (forward)
C4-04 (reverse)
C4-05
×
4
E1-09
Output frequency
Larger of b2-01
and E1-09
•
When using this compensation function, set the starting-torque compensation value to the friction load
in regular machinery or the lifting/lowering load for machinery such as cranes.
Friction loads:
Set the friction load in both C4-03 and C4-04.
Lifting/lowering load:
Set the electrically driven (winding) load only. (When the lifting machinery is equipped with a coun-
terweight, a shock may be generated if there is a regenerative load so do not use this function.)
•
It is only possible to set the electrically driven compensation in both forward and reverse. (The regen-
erative setting cannot be made.)
•
The starting-torque compensation is not applied when switching between forward and reverse or after
a speed search.
•
The starting-torque compensation is usually not applied when using a second motor.
Advanced Operation
Chapter 6
Содержание SYSDRIVE 3G3FV
Страница 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Страница 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Страница 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Страница 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Страница 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Страница 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Страница 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...