1-11
1-3
New Functions
The following software versions have been implemented for the 3G3FV Series to add
and upgrade functions.
August 1996: Software Ver. VSG101032 (S1032)
April 1997:
Software Ver. VSG101040 (S1040)
Sept. 1998:
Software Ver. VSG101043 (S1043)
Sept. 1999:
Software Ver. VSG101113 (S1113)
Sept. 2000:
Software Ver. VSG101114 (S1114)
The software version can be confirmed using the 5-digit number display for the FLASH
ID for U1-14.
This section describes the new functions and improvements for each software version.
Refer to
Chapter 5 Basic Operation and Chapter 6 Advance Operation.
1-3-1 Software Ver. VSG101040
H
CompoBus/D (DeviceNet) Communications Card
The CompoBus/D Communications Card can be used to connect the Inverter to a DeviceNet network.
The following function additions and improvements were made to support this new functionality.
D
CompoBus/D Addition to the Frequency Reference Selection (Parameter b1-01)
A function was added to Frequency Reference Selection so that the Inverter frequency reference can
be input via DeviceNet communications.
D
CompoBus/D Addition to the Run Source Selection (Parameter b1-02)
A function was added to Run Source Selection so that the Inverter run command can be input via Devi-
ceNet communications.
D
Communications External Fault Input (Parameters F9-01 to F9-03)
A function was added to support an external fault input from DeviceNet communications to stop the
Inverter when an error occurs. Sequence settings and operation designation for errors for the commu-
nications external fault input have been added.
H
Two-motor Switching Control
A function was added to enable switching control between two motors using one Inverter. The following
function additions were made to support this new functionality.
D
Control Mode Setting Second Motor (Parameter E3-01)
A control mode setting was added so that the second motor can be set to a different mode.
Note The control mode setting was limited to 0 (
V/f control without PG) or 2 (open-loop vector control), but
was changed in system version VSG101043 to support all control modes 0 to 3.
D
V/f Pattern Settings for Second Motor (Parameters E4-01 to E4-06)
V/f pattern settings were added so that the second motor can be set to a different pattern.
Introduction
Chapter 1
Содержание SYSDRIVE 3G3FV
Страница 1: ...USER S MANUAL High function General purpose Inverter SYSDRIVE 3G3FV Cat No I516 E1 4 ...
Страница 16: ...Chapter 1 Introduction 1 1 Function 1 2 Nomenclature 1 3 New Functions 1 ...
Страница 33: ...Chapter 2 Installation 2 1 Mounting 2 2 Wiring 2 ...
Страница 112: ...Chapter 4 Trial Operation 4 1 Procedure 4 2 Operation Example 4 ...
Страница 289: ...Chapter 7 Parameter Lists 7 1 Initialize Mode Parameters 7 2 Program Mode Parameter List 7 ...
Страница 366: ...Chapter 9 Specifications 9 1 Inverter Specifications 9 2 Option Specifications 9 ...
Страница 395: ...Chapter 10 Appendix 10 1 Notes on Using the Inverter for a Motor 10 ...