358
SIEPCYEUOQ2V01A Q2V Technical Manual
Setting Value
Function
Description
Ref.
4D
Motor OL1
The terminal activates when the electronic thermal protection value of the motor overload protective function is a
minimum of 90% of the detection level.
4E
Drive PreOH
The terminal activates when the drive heatsink temperature is at the level set with
L8-02 [Overheat Alm Level]
.
4F
PreOHTimeLim
The terminal activates when
L8-03 = 4 [Overheat Pre-Alarm Selection = Run@L8-19 Rate]
and
oH [Heatsink
Overheat]
does not clear after the drive decreases the frequency for 10 cycles.
60
BrkTransFault
The terminal activates when the internal braking transistor overheats and the drive detects an
rr [Dynamic Braking
Transistor Fault]
fault.
61
BrkTransOH
The terminal activates when the braking resistor overheats and the drive detects an
rH [Braking Resistor Overheat]
fault.
63
Maintenance
The terminal activates when drive components are at their estimated maintenance period.
Tells the user about the maintenance period for these items:
•
IGBT
•
Cooling fan
•
Capacitor
•
Soft charge bypass relay
65
WattH Pulse
Outputs the pulse that shows the watt hours.
66
MechWeakDetect
The terminal activates when the drive detects mechanical weakening.
67
ModbusReg 1
The terminal activates when the bit specified by
H2-08 [Mbus Reg1 Bit Select]
for the Modbus register address set
with
H2-07 [Mbus Reg1 Address Select]
activates.
69
ModbusReg 2
The terminal activates when the bit specified by
H2-10 [Mbus Reg2 Bit Select]
for the Modbus register address set
with
H2-09 [Mbus Reg2 Address Select]
activates.
6A
DataLog Error
The terminal activates when the drive detects
LoG [Com Error / Abnormal SD card]
.
90 - 92
Q2pack DO1 to 3
Sets the Q2pack digital output. Refer to the Q2pack online manual for more information.
100 - 192
Inverse output of 0 to 92
Causes inverse output of the function for the selected MFDO. Uses the last two digits of 1xx to select which
function to inversely output.
◆
H3: ANALOG INPUTS
No.
(Hex.)
Name
Description
Default
(Range)
Ref.
H3-01
(0410)
AI1 Signal Level Select
Sets the input signal level for MFAI terminal AI1.
0 : 0 to 10V (Lower Limit at 0)
1 : 0 to +10 V (Without Lower Limit)
0
(0, 1)
H3-02
(0434)
AI1 Function Selection
Sets the function for MFAI terminal AI1.
0
(0 - 32)
H3-03
(0411)
RUN
AI1 Gain Setting
Sets the gain of the analog signal input to MFAI terminal AI1.
100.0%
(-999.9 - +999.9%)
H3-04
(0412)
RUN
AI1 Bias Setting
Sets the bias of the analog signal input to MFAI terminal AI1.
0.0%
(-999.9 - +999.9%)
H3-09
(0417)
AI2 Signal Level Select
Sets the input signal level for MFAI terminal AI2.
0 : 0 to 10V (Lower Limit at 0)
1 : 0 to +10V (Without Lower Limit)
2 : 4 to 20 mA
3 : 0 to 20 mA
2
(0 - 3)
H3-10
(0418)
AI2 Function Selection
Sets the function for MFAI terminal AI2.
0
(0 - 32)
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...