688
SIEPCYEUOQ2V01A Q2V Technical Manual
■
n8-49: Heavy Load Id Current
No.
(Hex.)
Name
Description
Default
(Range)
n8-49
(053C)
RUN
Expert
Heavy Load Id Current
Sets the d-axis current to that the drive will supply to the motor to run it at a constant speed with a
heavy load. Considers
E5-03 [PM Mot Rated Current (FLA)]
to be 100%. Usually it is not
necessary to change this setting.
Determined by E5-01
(-200.0 - +200.0%)
When you use an IPM motor, you can use the reluctance torque of the motor to make the motor more efficient and
help conserve energy.
When you operate an SPN motor, set this parameter to 0.
Adjust in the following situations.
•
If the load is large and motor rotation is not stable, decrease the setting value.
•
When you change
E5: PM MOTOR SETTINGS
, set
n8-49 = 0
, then adjust this parameter.
■
n8-50: Medium Load Iq Level (High)
No.
(Hex.)
Name
Description
Default
(Range)
n8-50
(053D)
Expert
Medium Load Iq Level
(High)
Sets the load current level at which heavy load control starts where
E5-03 [PM Mot Rated Current
(FLA)]
is 100%. Usually it is not necessary to change this setting.
80%
(50 - 255)
■
n8-51: Ac/Dec Pull-In Current
No.
(Hex.)
Name
Description
Default
(Range)
n8-51
(053E)
Ac/Dec Pull-In Current
Sets the pull-in current allowed to flow during acceleration/deceleration as a percentage of the
motor rated current.
Determined by A1-02
(0 - 200%)
Adjust in the following situations.
•
When the motor does not smoothly because of large loads, increase the setting value in 5% increments.
•
If too much current flows during acceleration, decrease the setting value.
Note:
When
A1-02 = 8 [Control Method = EZ Vector]
, this parameter will always be in effect for speed ranges less than
n7-10 [Pull-in
SwitchSpeed]
.
■
n8-54: Volt-Err Compensation Time
No.
(Hex.)
Name
Description
Default
(Range)
n8-54
(056D)
Expert
Volt-Err Compensation
Time
Sets the time constant that the drive uses when adjusting for voltage errors.
1.00 s
(0.00 - 10.00 s)
Adjust this parameter in these conditions:
•
If oscillation occurs at the time of start up, increase the setting value.
•
If hunting occurs when operating at low speed, increase the setting value.
•
If fast changes in the load cause hunting, increase the setting value in 0.1-unit increments. If you cannot stop
hunting, set
n8-51 [Ac/Dec Pull-In Current]
to 0% and set
n8-54
to 0.00 s, and disable compensation for voltage
errors.
■
n8-55: Load Inertia
No.
(Hex.)
Name
Description
Default
(Range)
n8-55
(056E)
Load Inertia
Sets the ratio between motor inertia and machine inertia.
1
(1 - 4)
Adjust in the following situations.
•
If torque and speed response is unsatisfactory, gradually increase the setting from 0.
•
If the motor does not run smoothly, gradually increase the setting from 0.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...