SIEPCYEUOQ2V01A Q2V Technical Manual
545
The output turns off and the motor coasts to stop. The output terminal set for
Fault [H2-01 to H2-03 = 3]
activates.
2 : Fast Stop (C1-09)
The drive stops the motor in the deceleration time set in
C1-09 [Fast Stop Time]
. The output terminal set for
Fault
[H2-01 to H2-03 = 3]
activates.
3 : Alarm Only
The keypad shows
oS
and the drive continues operation. Only use this setting in special conditions to prevent
damage to the motor and machinery. The output terminal set to
Alarm [H2-01 to H2-03 = 4]
activates.
Note:
•
When
A1-02 = 0 [Control Method = V/f Control]
, set
H6-01 = 3 [PI Pulse Train Function = PG Feedback]
to enable this parameter.
•
When
A1-02 = 6 [Control Method = PM AOLVector]
, the drive will automatically set
F1-03 = 1 [Coast->Stop]
. You cannot change
this value.
■
F1-04: Speed Dev Detection Select
No.
(Hex.)
Name
Description
Default
(Range)
F1-04
(0383)
Speed Dev Detection Select
Sets the method to stop the motor or let the motor continue to operate when the drive detects
dEv
[Speed Deviation]
.
3
(0 - 3)
When the difference between the frequency reference and the motor speed is more than the value set in
F1-10
[Speed Dev Level]
for longer than the time set in
F1-11 [Speed Dev Delay Time]
, it will trigger
dEv
.
Note:
When
A1-02 = 0 [Control Method = V/f Control]
, set
H6-01 = 3 [PI Pulse Train Function = PG Feedback]
to enable this parameter.
0 : Ramp->Stop
The drive ramps the motor to stop in the deceleration time. The output terminal set for
Fault [H2-01 to H2-03 =
3]
activates.
1 : Coast->Stop
The output turns off and the motor coasts to stop. The output terminal set for
Fault [H2-01 to H2-03 = 3]
activates.
2 : Fast Stop (C1-09)
The drive stops the motor in the deceleration time set in
C1-09 [Fast Stop Time]
. The output terminal set for
Fault
[H2-01 to H2-03 = 3]
activates.
3 : Alarm Only
The keypad shows
dEv
and the drive continues operation. Only use this setting in special conditions to prevent
damage to the motor and machinery. The output terminal set to
Alarm [H2-01 to H2-03 = 4]
activates.
■
F1-08: Overspeed Level
No.
(Hex.)
Name
Description
Default
(Range)
F1-08
(0387)
Overspeed Level
Sets the detection level of
oS [Overspeed]
as a percentage when the maximum output frequency
is 100%.
115%
(0 - 120%)
When the motor speed is more than the value set in
F1-08
for longer than the time set in
F1-09 [Overspeed Delay
Time]
, the drive will detect
oS
.
Note:
When
A1-02 = 0 [Control Method = V/f Control]
, set
H6-01 = 3 [PI Pulse Train Function = PG Feedback]
to enable this parameter.
■
F1-09: Overspeed Delay Time
No.
(Hex.)
Name
Description
Default
(Range)
F1-09
(0388)
Overspeed Delay Time
Sets the length of time that the speed feedback must be more than the
F1-08
level to cause
oS
[Overspeed]
.
Determined by A1-02
(0.0 - 2.0 s)
When the motor speed is more than the value set in
F1-08 [Overspeed Level]
for longer than the time set in
F1-
09
, the drive will detect
oS
.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...