SIEPCYEUOQ2V01A Q2V Technical Manual
589
■
H2-01: NO,NC,CM FuncSelection
No.
(Hex.)
Name
Description
Default
(Range)
H2-01
(040B)
NO,NC,CM FuncSelection
Sets the function set for MFDO terminal NO-CM or NC-CM.
3
(0 - 1FF)
Note:
Set this parameter to
0
when the terminal is not being used or to use the terminal in through mode.
■
H2-02: DO1-O1C Func Selection
No.
(Hex.)
Name
Description
Default
(Range)
H2-02
(040C)
DO1-O1C Func Selection
Sets the function for MFDO terminal DO1-O1C.
5
(0 - 1FF)
Note:
Set this parameter to
0
when the terminal is not being used or to use the terminal in through mode.
■
H2-03: DO2-O2C Func Selection
No.
(Hex.)
Name
Description
Default
(Range)
H2-03
(040D)
DO2-O2C Func Selection
Sets the function for MFDO terminal DO2-O2C.
F
(0 - 1FF)
Note:
Set this parameter to
0
when the terminal is not being used or to use the terminal in through mode.
■
H2-06: kWH Out Unit Selection
No.
(Hex.)
Name
Description
Default
(Range)
H2-06
(0437)
kWH Out Unit Selection
Sets the unit for the output signal when
H2-01 to H2-03 = 65 [MFDO Function Select = WattH
Pulse]
.
1
(1 - 5)
This output is input to the Watt hour meter or PLC through a 200 ms pulse signal. This parameter sets the kWh
unit for each pulse output.
Figure 12.75 Example MFDO when Configured for Watt Hours
Note:
•
When the power value is a negative value (regenerative state), the drive does not count Watt hours.
•
When the control power supply to the drive is operating, the drive will keep the Watt hours. If a momentary power loss causes the drive
to lose control power, the Watt hour count will reset.
1 : 0.1 kWh units
2 : 1 kWh units
3 : 10 kWh units
4 : 100 kWh units
5 : 1000 kWh units
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...