356
SIEPCYEUOQ2V01A Q2V Technical Manual
Setting Value
Function
Description
Ref.
11
SpeedAgree2
The terminal activates when the output frequency is in the range of the frequency reference ±
L4-04 [SpAgree Det.
Width(+/-)]
.
Note:
The detection function operates in the two motor rotation directions.
ON : The output frequency is in the range of
“
frequency reference ±
L4-04
”
.
OFF : The output frequency is not in the range of
“
frequency reference ±
L4-04
”
.
12
USpeedAgree2
The terminal activates when the output frequency is in the range of
L4-03 [SpAgree Det.Level(+/-)]
±
L4-04
[SpAgree Det.Width(+/-)]
and in the range of the frequency reference ±
L4-04
.
Note:
The detection level set with
L4-03
is a signed value. The drive will only detect in one direction.
ON : The output frequency is in the range of
“
L4-03
±
L4-04
”
and the range of frequency reference ±
L4-04
.
OFF : The output frequency is not in the range of
“
L4-03
±
L4-04
”
nor the range of frequency reference ±
L4-04
.
13
FreqDetect 1
The terminal deactivates when the output frequency is higher than the value of
L4-01 [SpAgree Det.Level] + L4-02
[SpAgree Det.Width]
. After the terminal turns off, the terminal continues to remain off until the output frequency
reaches the level set with
L4-01
.
Note:
The detection function operates in the two motor rotation directions. The drive uses the
L4-01
value as the
forward/reverse detection level.
ON : The output frequency is less than the value of
L4-01
or does not exceed the value of
L4-01
+
L4-02
.
OFF : The output frequency is higher than the value of
L4-01
+
L4-02
.
14
FreqDetect 2
The terminal activates when the output frequency is higher than the value of
L4-01 [SpAgree Det.Level]
. After the
terminal activates, the terminal stays activated until the output frequency is at the value of
L4-01
-
L4-02
.
Note:
The detection function operates in the two motor rotation directions. The drive uses the
L4-01
value as the
forward/reverse detection level.
ON : The output frequency is higher than the value of
L4-01
.
OFF : The output frequency is less than the value of
“
L4-01
-
L4-02
,
”
or it does not exceed the value of
L4-01
.
15
FreqDetect 3
The terminal deactivates when the output frequency is higher than the value of
“
L4-03 [SpAgree Det.Level(+/-)]
+
L4-04 [SpAgree Det.Width(+/-)]
”
. After the terminal deactivates, the terminal stays deactivated until the output
frequency is at the value of
L4-03
.
Note:
The detection level set with
L4-03
is a signed value. The drive will only detect in one direction.
ON : The output frequency is less than the value of
L4-03
or does not exceed the value of
L4-03
+
L4-04
.
OFF : The output frequency is higher than the value of
L4-03
+
L4-04
.
16
FreqDetect 3
The terminal activates when the output frequency is higher than the value of
L4-03 [SpAgree Det.Level(+/-)]
. After
the terminal activates, the terminal stays activated until the output frequency is at the value of
L4-03
-
L4-04
.
Note:
The detection level set with
L4-03
is a signed value. The drive will only detect in one direction.
ON : The output frequency is higher than the value of
L4-03
.
OFF : The output frequency is less than the value of
“
L4-03
-
L4-04
,
”
or it does not exceed the value of
L4-03
.
17
@Fast Stop
The terminal activates when the fast stop is in operation.
18
@KEBridethru
The activates during KEB Ride-Thru.
19
@ShortCBraking
The terminal activates during Short Circuit Braking.
Note:
When
A1-02 = 8 [Control Method = EZ Vector]
, this function is available when you use a PM motor.
1A
@BaseblockNO
The terminal turns on during baseblock. When the drive is in baseblock, the drive output transistor stops switching
and does not make DC bus voltage.
ON : During baseblock
OFF : The drive is not in baseblock.
1B
@BaseblockNC
The terminal deactivates during baseblock. When the drive is in baseblock, the drive output transistor stops
switching and does not make DC bus voltage.
ON : The drive is not in baseblock.
OFF : During baseblock
1C
FreqRefSource
Shows the selected frequency reference source.
ON : The keypad is the frequency reference source.
OFF : Parameter
b1-01 or b1-15 [Freq. Ref. Sel. 1 or Freq. Ref. Sel. 2]
is the frequency reference source.
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
V/f
OLV
OLV/PM
OLV/PM AOLV/PM
EZOLV
Содержание Q2V Series
Страница 2: ...This Page Intentionally Blank 2 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 12: ...12 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 18: ...i 2 Legal Information 18 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 26: ...1 2 Features and Advantages of Control Methods 26 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 38: ...2 8 Installation Methods 38 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 70: ...3 3 Main Circuit Wiring 70 SIEPCYEUOQ2V01A Q2V Technical Manual Models B006 B012...
Страница 102: ...3 17 Motor Application Precautions 102 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 138: ...4 12 Test Run Checklist 138 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 143: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 143 EU Declaration of Conformity...
Страница 144: ...5 2 European Standards 144 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 145: ...Standards Compliance 5 5 2 European Standards SIEPCYEUOQ2V01A Q2V Technical Manual 145...
Страница 146: ...5 2 European Standards 146 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 266: ...7 10 Troubleshooting Without Fault Display 266 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 284: ...8 6 Storage Guidelines 284 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 312: ...10 10 Peripheral Devices and Options 312 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 430: ...11 21 Parameters Changed by PM Motor Code Selection 430 SIEPCYEUOQ2V01A Q2V Technical Manual...
Страница 731: ...SIEPCYEUOQ2V01A Q2V Technical Manual 731 Z Z pulse Auto Tuning 125...
Страница 733: ...SIEPCYEUOQ2V01A Q2V Technical Manual 733...