3-46
D
R88D-UP20H(A)/-UP20V (750 W)
Applicable load inertia
(
×
10
–4
kg
S
m
2
)
700W 13.4
×
10
–4
kg
S
m
2
4.7
Rotation speed (r/min)
3-8-3 Absorption of Regenerative Energy with the External
Regeneration Resistor (Models Conforming to UL/cUL
Standards and Models Not Conforming to Any
Standards)
Connect one or more external regeneration resistors when a Regeneration Unit (R88A-
RG08UA) cannot absorb all of the regenerative energy. Remove the short bar from be-
tween the RG and JP terminals on the Regeneration Unit and connect the resistor be-
tween the P and RG terminals. Connecting to the wrong terminals may destroy the Re-
generation Unit, so connect the resistor carefully. (The Regeneration Unit does not con-
form to EC Directives.)
The external regeneration resistor will heat to approximately 120
_
C. Do not install it near
devices or wiring that is sensitive to heat. Install heat radiation plates suitable to the radi-
ation conditions.
H
External Regeneration Resistors
D
Models
Model
Resistance
Nominal
capacity
Regeneration
absorption at
120
_
C
Heat
radiation
conditions
Thermal switch
output specifications
R88A-RR22047S 47
Ω ±
5%
220 W
70 W
t1.0
×
j
350
(SPCC)
Operating
temperature:
170
_
C
±
5%
N.C. contact
Rated output: 3 A