Item
R88D-UP15W
R88D-UP12W
R88D-UP10W
R88D-UP04W
R88D-UP03W
Input
signals
Position command pulse
input (see note)
TTL, line driver input with photoisolation, input current: 6 mA at 3 V
Feed pulse and direction signal, forward pulse and reverse pulse, or 90
_
differen-
tial phase (A and B phases) signal (set via parameter). Pulse width: See note.
Deviation counter reset
TTL, line driver input with photoisolation, input current: 6 mA at 3 V
Sequence input
24-VDC, 5-mA photocoupler input, external power supply: 24
±
1 VDC, 50 mA min.
Output
signals
Position feedback output
A-, B-, Z-phase line driver output (EIA RS-422A)
A-phase and B-phase (dividing rate setting): 16 to 2,048 pulses/revolution
Z-phase: 1 pulse/revolution
Speed monitor output
0.5 V/1,000 r/min
Current monitor output
0.5 V/100%
Sequence output
Alarm output, motor rotation detection, brake interlock, positioning completion;
open collector outputs: 30 VDC, 50 mA (except for alarm code output, which is 30
VDC, 20 mA)
External regeneration processing
Required for regeneration of more than 30 times the motor’s ro-
tor inertia.
Required for
regeneration
of more than
20 times the
motor’s rotor
inertia.
Protective functions
Overcurrent, grounding, overload, overvoltage, overspeeding, runaway protection,
transmission errors, encoder errors, deviation counter overflow
Note The input pulse width must be meet the following conditions.
T
IL
,T
IH
≥
2.5
µ
s
H
L
T
IH
T
IL
5-1-3 I/O Specifications
H
Terminal Block Specifications, Models Conforming to UL/cUL
Standards and Models Not Conforming to Any Standards
Signal
Function
Condition
R
T
Power supply in-
put
R88D-UP
jj
H(A) (200-VAC Units): Single-phase 200/230 VAC (170 to
253 VAC) 50/60 Hz
R88D-UP
jj
L(A) (100-VAC Units): Single-phase 100/115 VAC (85 to
127 VAC) 50/60 Hz
P
N
Main circuit DC
output
These are the connection terminals for the Regeneration Unit
(R88A-RG08UA). Connect these when the regeneration energy is high.
U
Servomotor U-
phase output
Red
These are the terminals for outputs to the Servomotor.
V
Servomotor V-
phase output
White
W
Servomotor W-
phase output
Blue
Frame ground
Green
This is the connection terminal. Use a 100
Ω
or less (class-3) or bet-
ter ground. It is used in common for Servomotor output and power
supply input.
Specifications
Chapter 5