6-10
Terminal Connection Unit for C200H-NC211
XW2B-40J6-2B
Note:
Terminal block pitch: 7.62 mm
C200H-NC211 connector
X-axis Servo Driver
connector
Y-axis Servo Driver
connector
Two, 3.5 dia.
X/Y-axis
emergency
stop
X-axis
CW
limit
X-axis
CCW
limit
X-axis
origin
proximity
X-axis
RUN
X-axis
MING
X-axis
ALM
X-axis
BKIR
Y-axis
CW
limit
Y-axis
CCW
limit
Y-axis
origin
proximity
Y-axis
RUN
Y-axis
MING
Y-axis
ALM
Y-axis
BKIR
Com-
mon
X-axis
external
interrupt
X-axis
RESET
24
VDC
X-axis
ALMCOM
(See
note 1)
Y-axis
external
interrupt
24
VDC
(See note 1)
Y-axis
RESET
Y-axis
ALMCOM
24 VDC
Com-
mon
Com-
mon
Com-
mon
Com-
mon
Com-
mon
Com-
mon
Com-
mon
Com-
mon
Note 1. The XB contact is used to turn ON/OFF the electromagnetic brake.
Note 2. Connect the CW and CCW limit signals to a common terminal when controlling one axis.
Note 3. Do not connect unused terminals.
Note 4. The 0 V terminal is internally connected to the common terminals.
Note 5. The following crimp terminal is applicable: R1.25-3 (round with open end).