2-2-3 Wiring Servo Drivers
Provide proper wire diameters, ground systems, and noise resistance when wiring terminal blocks.
H
Wiring Terminal Blocks
To Motor
Power Cable
R88A-CAU
jjj
S
R88A-CAU
jjj
B (with brake)
(The broken lines indicate signal
lines for the brake. There is no
polarity on these lines.)
Power supply input terminals
Main-circuit DC output terminals
Red
White
Blue
Green
Black
Black
24 VDC
Terminal
label
Name
Function
R
Power supply
input
The commercial power supply input terminals for the main circuit and the
control circuitry.
T
y
R88D-UP
jj
H(A): Single-phase 200/230 VAC (170 to 253 V) 50/60 Hz
R88D-UP
jj
L(A): Single-phase 100/115 VAC (85 to 127 V) 50/60 Hz1
P
Main circuit DC
The terminals for connecting Regeneration Units (R88A-RG08UA). Connect
h
i
l
h
h
i
hi h l
l f
i
(S
)
N
output
g
g
(
)
these terminals when there is a high level of regenerative energy. (See note.)
U
Motor connection
i
l
Red
These are the output terminals to the Servomotor. Be careful to wire
h
l
V
terminals
White
them correctly.
W
Blue
Frame ground
Green The ground terminal for both the motor output and power supply in-
put. Ground to a class-3 ground (to 100
Ω
or less) or better.
Note Refer to
3-8 Regenerative Energy Absorption for the methods to calculate regenerative energy.
System Design and Installation
Chapter 2