5. Installation and Wiring
5-9
General-Purpose Output Terminal
5.5.3.
■
Checking Input/Output Specifications
Check the input/output specifications of the general-purpose input/output terminals. Applying a
voltage over the rated one to the input terminal, or a voltage over the maximum load voltage to
an output terminal, may result in a failure, disruption, or fire.
Be careful not to connect positive and negative terminals oppositely, if specified.
■
Terminal Screw and Crimping Terminal
Terminal Screw
M3 captive screw
Recommended Wire Size
AWG22 to 18 (0.326 to 0.823 mm
2
)
Recommended Tightening Torque
0.5 N
⋅
m
Recommended Crimping Terminal
(Unit: mm)
Precautions
- Use proper crimping terminals to the terminal block for wiring.
- Make sure to apply torque of 0.5 N
⋅
m to the terminal screws.
6.
2以
下
φ3.2
6.
2以
下
3
.2
<6.2
<6.2
3.2 dia.