7.5
Setting up a feedback device
7.5.1
P1 position interface
This section shows the parameter settings which must be made to use each of the compatible feedback device types with P1 position interface on the
drive. For more information on the parameters listed here please refer to the
Parameter Reference Guide.
Table 7-3 Parameters required for feedback device set-up on the P1 position interface
Information required to be entered by the user.
●
Parameter can be set-up automatically by the drive through auto-configuration parameter. Must be set by the user if auto-configuration is disabled
(i.e. Pr
03.041
= Disabled (0)).
*
Pr
03.036
: If the output voltage from the encoder is > 5 V, then termination resistors must be disabled by setting Pr
03.039
to 0.
Table 7-3 shows a summary of the parameters required to set-up each feedback device. More detailed information follows.
Parameter
AB, FD, FR, AB Servo,
SC, SC Servo, SC SC
FD Servo, FR Servo
SC
Hiperface
SC
EnDat
SC
BiSS
SC
SSI
SSI
EnDat BiSS
Resolver
P1 Marker Mode
(03.031)
P1 Rotary Turns Bits
(03.033)
●
●
●
●
●
P1 Rotary Lines Per Revolution
(03.034)
●
●
●
P1 Comms Bits
(03.035)
●
●
●
●
●
P1 Supply Voltage
(03.036)*
P1 Comms Baud Rate
(03.037)
P1 Device Type
(03.038)
P1 Auto–configuration Select
(03.041)
P1 SSI Binary Mode
(03.048)
P1 Calculation time
(03.060)
P1 Resolver Poles
(03.065)
P1 Resolver Excitation
(03.066)
P1 Additional Configuration
(03.074)
●
●