Digitax HD M753 Control User Guide
233
Issue Number: 3
Encoder 7
Set-up parameters for position feedback device have changed
195
The
Encoder 7
trip indicates that the set-up parameters for position feedback device has changed. The feedback device
which has caused the trip can be identified by the sub-trip number.
Recommended actions:
•
Reset the trip and perform a save.
•
Ensure Pr
3.033
and Pr
03.035
are set correctly or carry out an encoder auto-configuration (Pr
03.041
= Enabled)
Encoder 8
Position feedback interface has timed out
196
The
Encoder 8
trip indicates that Position feedback interface communications time exceeds 250
s. The feedback device
which has caused the trip can be identified by the sub-trip number.
Recommended actions:
•
Ensure the encoder is connected correctly
•
Ensure that the encoder is compatible
•
Increase baud rate
Encoder 9
Position feedback is selected from a option module slot which does not have a feedback option module installed
197
The
Encoder 9
trip indicates that position feedback source selected in Pr
03.026
(or Pr
21.021
for the second motor map) is
not valid
Recommended actions:
•
Check the setting of Pr
03.026
(or Pr
21.021
if the second motor parameters have been enabled)
•
Ensure that the option slot selected in Pr
03.026
has a feedback option module installed
Encoder 12
Encoder could not be identified during auto-configuration
162
The
Encoder 12
trip indicates that the drive is communicating with the encoder but the encoder type is not recognized.
Recommended actions:
•
Enter the encoder setup parameters manually
•
Check to see the encoder supports auto-configuration
Encoder 13
Data read from the encoder is out of range during auto-configuration
163
The
Encoder 13
trip indicates that the data read from the encoder was out of the range during auto-configuration. No
parameters will be modified with the data read from the encoder as a result of auto configuration. The tens in the sub-trip
number indicate the interface number (i.e. 1 for P1 interface and 2 for P2 interface).
Recommended actions:
•
Enter the encoder setup parameters manually
•
Check to see the encoder supports auto-configuration
Trip
Diagnosis
Sub-trip
Reason
1
Drive position feedback interface 1
2
Drive position feedback interface 2
Sub-trip
Reason
1
Drive position feedback interface 1
2
Drive position feedback interface 2
Sub-trip
Reason
1
Drive position feedback interface 1
2
Drive position feedback interface 2
Sub-trip
Reason
x1
Rotary lines per revolution error
x2
Linear comms pitch error
x3
Linear line pitch error
x4
Rotary turns bits error
x5
Communications bits error
x6
Calculation time is too long
x7
Line delay measured is longer than 5 µs
Содержание Digitax HD M753 EtherCAT