Select the discovered drive.
1. Select the ‘Online’ icon to connect with the drive. When a successful connection is made the icon will be highlighted blue.
2. Select ‘Set mode and region’.
If the required control mode is highlighted in the ‘Drive Settings’ dialog, then:
•
Change the supply frequency if required and select ‘Apply’, otherwise select ‘Cancel’.
If the required control mode is not highlighted in the ‘Drive Settings’ dialog then:
•
Select the required mode and supply frequency.
•
Select ‘Apply’.
Select ‘Default parameters‘ from the Dashboard and in the ‘Default Parameters’ dialog, select ‘Apply’.
3. Select ‘Setup’ and perform the steps highlighted:
4. Select 'Save parameters in drive' to perform a parameter save. The drive is now ready to run.
1
2
3
4
Action
Detail
Motor set-up
Connect contains a database for induction motors and permanent magnet motors. Provision is also made to enter motor
nameplate data.
Motor feedback set-up
This only needs to be performed in RFC-S and RFC-A (with feedback) modes. Enter the encoder type and encoder
configuration data as prompted on screen.
If output voltage from the encoder is > 5 V, then the termination resistors must be disabled Pr
03.039
to 0.
Speed references
Enter preset speeds or a jog reference if required.
Ramps set-up
Enter the required Acceleration rate and Deceleration rate.
Note: If a braking resistor is installed, set 'Ramp mode' to 'Fast'. Also ensure Pr
10.030
and Pr
10.031
and Pr
10.061
are set
correctly, otherwise premature 'Brake R Too Hot' trips may be seen.
I/O set-up
Map I/O terminals to parameters (where non default configuration is required).
Analog I/O
Configure Analog input 1 and thermal monitoring parameters (where non default configuration is required).
Digital I/O
Allocate non default digital control functions to digital terminals where necessary.
Autotune
Follow the Autotune set up wizard to automatically tune the drive to the motor.
Not required when using data from the motor database for a Leroy Somer LSRPM motor used in RFC-S Sensorless mode.
NOTE
Setting the encoder voltage supply too high for the encoder could result in damage to the feedback device.
CAUTION
NOTE
Содержание Digitax HD M753 EtherCAT
Страница 261: ......
Страница 262: ...0478 0461 03...