Digitax HD M753 Control User Guide
249
Issue Number: 3
User Prog Trip
Trip generated by an onboard user program
96
This trip can be initiated from within an onboard user program using a function call which defines the sub-trip number
.
Recommended actions:
•
Check the user program
User Save
User Save error / not completed
36
The
User Save
trip indicates that an error has been detected in the user save parameters saved in non-volatile memory.
For example, following a user save command, If the power to the drive was removed when the user parameters were being
saved.
Recommended actions:
•
Perform a user save in Pr
mm.000
to ensure that the trip doesn’t occur the next time the drive is powered up.
•
Ensure that the drive has enough time to complete the save before removing the power to the drive.
User Trip
User generated trip
40 -89
112 -159
These trips are not generated by the drive and are to be used by the user to trip the drive through an application program.
Recommended actions:
•
Check the user program
Watchdog
Control word watchdog has timed out
30
The
Watchdog
trip indicates that the control word has been enabled and has timed out.
Recommended actions:
Once Pr
06.042
bit 14 has been changed from 0 to 1 to enable the watchdog, this must be repeated every 1 s or a
Watchdog trip will be initiated. The watchdog is disabled when the trip occurs and must be re-enabled if required when the
trip is reset.