Digitax HD M753 Control User Guide
47
Issue Number: 3
Table 6-2 Functions in Pr mm.000
on page 130 for more information on these functions.
** These functions do not require a drive reset to become active. All other functions require a drive reset to initiate the function. Equivalent values and
strings are also provided in the table above.
Value
Action
1000
Save parameters when
Under Voltage Active
(Pr
10.016
) is not active and
Low Under Voltage Threshold Select
mode (Pr
06.067
= Off)
is not active.
1001
Save parameters under all conditions
1070
Reset all option modules
1233
Load standard (50 Hz) defaults
1234
Load standard (50 Hz) defaults to all menus except option module menus (i.e 15 to 20 and 24 to 28)
1244
Load US (60 Hz) defaults
1245
Load US (60 Hz) defaults to all menus except option module menus (i.e 15 to 20 and 24 to 28)
1253
Change drive mode and load standard (50 Hz) defaults
1254
Change drive mode and load US (60 Hz) defaults
1255
Change drive mode and load standard (50 Hz) defaults except for menus 15 to 20 and 24 to 28
1256
Change drive mode and load US (60 Hz) defaults except for menus 15 to 20 and 24 to 28
1299
Reset {Stored HF} trip.
2001*
Create a boot file on a non-volatile media card based on the present drive parameters including all Menu 20 parameters
4yyy*
SD card: Transfer the drive parameters to parameter file xxx
5yyy*
SD card: Transfer the onboard user program to onboard user program file xxx
6yyy*
SD card: Load the drive parameters from parameter file xxx or the onboard user program from onboard user program file xxx
7yyy*
SD card: Erase file xxx
8yyy*
SD card: Compare the data in the drive with file xxx
9555*
SD card: Clear the warning suppression flag
9666*
SD card: Set the warning suppression flag
9777*
SD card: Clear the read-only flag
9888*
SD card: Set the read-only flag
59999
Delete onboard user program
110S0
Transfer electronic nameplate motor object parameters from the drive to an encoder connected to the drive or an option module.
110S1
Transfer electronic nameplate motor objects parameters from an encoder connected to the drive or option module to the drive
parameters.
110S2
As 110S0, but for performance object 1
110S3
As 110S1, but for performance object 1
110S4
As 110S0, but for performance object 2
110S5
As 110S1, but for performance object 2
110S6
Transfer electronic nameplate motor object parameters from the drive to an encoder connected to the drive or an option module in the
Unidrive SP format.
12000**
Only display parameters that are different from their default value. This action does not require a drive reset.
12001**
Only display parameters that are used to set-up destinations (i.e. DE format bit is 1). This action does not require a drive reset.
15xxx*
Transfer the user program in an option module installed in slot 1 to a non-volatile media card file xxx
16xxx*
Transfer the user program in an option module installed in slot 2 to a non-volatile media card file xxx
17xxx*
Transfer the user program in an option module installed in slot 3 to a non-volatile media card file xxx
18xxx*
Transfer the user program from file xxx in a non-volatile media card to an option module installed in slot 1.
19xxx*
Transfer the user program from file xxx in a non-volatile media card to an option module installed in slot 2.
20xxx*
Transfer the user program from file xxx in a non-volatile media card to an option module installed in slot 3.