AutoMAID level 5 is only available if all disks in the expansion unit are configured to go to AutoMAID 4. If
some of the disks are not configured for AutoMAID level 4, a warning appears:
There is one row for each expansion unit and four columns per row.
Enclosure Name
lists the “friendly” name of the expansion unit.
Current Setting
displays the amount of time that the system is currently set to wait before activating
AutoMAID level 5.
New Setting
displays a drop-down list with possible settings for AutoMAID level 5.
The last column displays the message
All levels compatible
if all disks in the enclosure are configured to
go to AutoMAID level 4. It displays the message
Incompatible AutoMAID levels
if any disks in the
enclosure are not configured for AutoMAID level 4.
►
To set the AutoMAID 5 settings for an expansion unit:
1. Using the New Setting drop-down list, select one of the following:
never
(the default)
All disks in level 4 + 5mins
All disks in level 4 + 30 mins
All disks in level 4 + 1 hr
2. Click the
Save Level 5 Settings
button.
A message is displayed, informing you that the settings have been changed. Click the
Back
button to return to
the
Configure AutoMAID Settings
page.
Chapter 3: The Graphical User Interface — Power Settings
Nexsan High-Density Storage
User Guide
187