To require CRC32 digests:
1. Check
Header Digest required
or
Data Digest required
, or both.
Note
This setting requires that the host support the appropriate CRC32 digests. If it doesn’t, the host
rejects the login.
2. Click
Apply Settings
.
►
To require CHAP authentication:
1. Select the
CHAP authentication
mode (
Target
or
Mutual
;
None
is the default).
2. Select the
CHAP secret
mode (
Use default host secrets
or
Use host unique secrets
).
If you select
Use host unique secrets
, enter a
Unique target secret
and a
Unique host secret
. Each
must be 12–32 characters long. The same host and target secrets must also be configured on the host
interface prior to iSCSI login.
Note
This setting requires that the host support the appropriate CHAP authentication mode. If it doesn’t,
the host rejects the login.
Note
If at any time you wish to return the
Host Configuration
page to its initial state, click
Reset
.
3. Click
Apply Settings
.
4. Click the gray arrow to return to the
Configure 10Ge iSCSI
page.