Troubleshooting 8-39
On-screen message
Description
Recommended action
Mem A Temp Alm 09
A high temperature alarm occurred in memory board A.
Mem A Temp Alm 02
A low temperature alarm occurred in memory board A.
Mem B Temp Alm 09
A high temperature alarm occurred in memory board B.
Mem B Temp Alm 02
A low temperature alarm occurred in memory board B.
Mem C Temp Alm 09
A high temperature alarm occurred in memory board C.
Mem C Temp Alm 02
A low temperature alarm occurred in memory board C.
Mem D Temp Alm 09
A high temperature alarm occurred in memory board D.
Mem D Temp Alm 02
A low temperature alarm occurred in memory board D.
1. Check if fans in the server work normally.
2. Check installation status of the failed memory board.
If the same error persists, contact your service representative.
PS1 Temp Alm 09
A high temperature alarm occurred in power supply unit #1.
PS1 Temp Alm 02
A low temperature alarm occurred in power supply unit #1.
PS2 Temp Alm 09
A high temperature alarm occurred in power supply unit #2.
PS2 Temp Alm 02
A low temperature alarm occurred in power supply unit #2.
1. Check if fans in the power supply unit work normally.
2. Check if fans in the server work normally.
3. Check installation status of the failed power supply unit.
If the same error persists, contact your service representative.
Proc1 Therm % 09
A high temperature alarm occurred in processor #1.
Proc1 Therm % 02
A low temperature alarm occurred in processor #1.
Proc2 Therm % 09
A high temperature alarm occurred in processor #2.
Proc2 Therm % 02
A low temperature alarm occurred in processor #2.
Proc3 Therm % 09
A high temperature alarm occurred in processor #3.
Proc3 Therm % 02
A low temperature alarm occurred in processor #3.
Proc4 Therm % 09
A high temperature alarm occurred in processor #4.
Proc4 Therm % 02
A low temperature alarm occurred in processor #4.
1. Check if fans in the server work normally.
2. Check installation status of the failed processor and processor heat
sink.
If the same error persists, contact your service representative.
AC lost Alm 1
The power supply unit #1 failed to supply AC power.
AC lost Alm 2
The power supply unit #2 failed to supply AC power.
1. Check connection status of AC power cord of failed power supply unit.
2. Turn off the DC power of the server, and disconnect the AC power
cord. Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Содержание Express5800/140Rf-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 20: ...x This page is intentionally left blank ...
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 235: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 264: ...7 18 Maintenance This page is intentionally left blank ...
Страница 397: ...9 64 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 413: ...C 4 This page is intentionally left blank ...
Страница 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...