Troubleshooting 8-35
Messages displayed on lower line (BMC Message)
When STATUS lamp is off
On-screen
message
Description
Recommended action
SMI Timeout
A timeout error occurred during system management interrupt.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
DUMP Request!
DUMP switch was pressed.
Wait until OS dump process completes.
If the dump process is not complete, take one of the following steps.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Proc1 Thermal Trip
Forced power-off occurred due to a thermal error in processor #1.
Proc2 Thermal Trip
Forced power-off occurred due to a thermal error in processor #2.
Proc3 Thermal Trip
Forced power-off occurred due to a thermal error in processor #3.
Proc4 Thermal Trip
Forced power-off occurred due to a thermal error in processor #4.
1. Reboot (reset) the server.
2. Check if fans in the server work normally.
3. Check installation status of failed processor.
4. Replace the failed processor.
If the same error persists, contact your service representative.
Proc1 IERR
An internal error (IERR) was detected in processor #1.
Proc2 IERR
An internal error (IERR) was detected in processor #2.
Proc3 IERR
An internal error (IERR) was detected in processor #3.
Proc4 IERR
An internal error (IERR) was detected in processor #4.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the failed rocessor.
4. Replace the failed processor.
If the same error persists, contact your service representative.
Содержание Express5800/140Rf-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 20: ...x This page is intentionally left blank ...
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 235: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 264: ...7 18 Maintenance This page is intentionally left blank ...
Страница 397: ...9 64 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 413: ...C 4 This page is intentionally left blank ...
Страница 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...