8-32 Troubleshooting
On-screen
message
Description
Recommended action
PCIE C Err (x)
A correctable error occurred on PCI Express bus.
Reboot (reset) the server, though you may continue use or run the system.
If the same error persists, contact your service representative.
Chipset C Err (x)
A correctable error occurred on chipset.
Reboot (reset) the server, though you may continue use or run the system.
If the same error persists, contact your service representative.
FBD CH(x) C Err
A correctable error occurred on memory board in the following location.
(x): Memory board that contains the failed DIMM.
A: Memory board A
B: Memory board B
C: Memory board C
D: Memory board D
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed memory board.
3. Check installation status of DIMM on the failed memory board.
If the same error persists, contact your service representative.
Sparing FailOver
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM (in memory sparing configuration).
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed DIMMs.
3. Replace the failed DIMMs.
If the same error persists, contact your service representative.
Mirror FailOver
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMM (in memory mirroring configuration).
Mirror B1 Fail
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMMs on memory board A or B (in memory mirroring configuration).
Mirror B2 Fail
Memory mirror failover occurred due to an uncorrectable error occurred on
DIMMs on memory board C or D (in memory mirroring configuration).
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check installation status of failed DIMMs.
3. Replace the failed DIMMs.
If the same error persists, contact your service representative.
SB C Err (x)
A correctable error occurred on SAS riser board.
You may continue use or run the system, however, try the following steps.
1. Reboot (reset) the server.
2. Check cable connection between SAS riser board.
3. Check installation status of SAS riser board.
If the same error persists, contact your service representative.
Содержание Express5800/140Rf-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 20: ...x This page is intentionally left blank ...
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 235: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 264: ...7 18 Maintenance This page is intentionally left blank ...
Страница 397: ...9 64 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 413: ...C 4 This page is intentionally left blank ...
Страница 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...