8-38 Troubleshooting
On-screen message
Description
Recommended action
BB +3.3Vs Alm 09
+3.3Vs voltage alarm (upper limit) occurred.
BB +3.3Vs Alm 02
+3.3Vs voltage alarm (lower limit) occurred.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power
cord. Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
IO +3.3V AUX Alm 09
+3.3V AUX voltage alarm (upper limit) occurred on I/O riser board.
IO +3.3V AUX Alm 02
+3.3V AUX voltage alarm (lower limit) occurred on I/O riser board.
IO +1.8Vs Alm 09
+1.8Vs voltage alarm (upper limit) occurred on I/O riser board.
IO +1.8Vs Alm 02
+1.8Vs voltage alarm (lower limit) occurred on I/O riser board.
IO +1.2Vs Alm 09
+1.2Vs voltage alarm (upper limit) occurred on I/O riser board.
IO +1.2Vs Alm 02
+1.2Vs voltage alarm (lower limit) occurred on I/O riser board.
IO +1.0Vs Alm 09
+1.0Vs voltage alarm (upper limit) occurred on I/O riser board.
IO +1.0Vs Alm 02
+1.0Vs voltage alarm (lower limit) occurred on I/O riser board.
IO +12V Alm 09
+12V voltage alarm (upper limit) occurred on I/O riser board.
IO +12V Alm 02
+12V voltage alarm (lower limit) occurred on I/O riser board.
IO +5V Alm 09
+5V voltage alarm (upper limit) occurred on I/O riser board.
IO +5V Alm 02
+5V voltage alarm (lower limit) occurred on I/O riser board.
IO +3.3V Alm 09
+3.3V voltage alarm (upper limit) occurred on I/O riser board.
IO +3.3V Alm 02
+3.3V voltage alarm (lower limit) occurred on I/O riser board.
IO +1.5V Alm 09
+1.5V voltage alarm (upper limit) occurred on I/O riser board.
IO +1.5V Alm 02
+1.5V voltage alarm (lower limit) occurred on I/O riser board.
IO +1.0V Alm 09
+1.0V voltage alarm (upper limit) occurred on I/O riser board.
IO +1.0V Alm 02
+1.0V voltage alarm (lower limit) occurred on I/O riser board.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power
cord. Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the I/O riser board.
If the same error persists, contact your service representative.
Battery Alm 09
A voltage alarm (upper limit) occurred on lithium battery.
Battery Alm 02
A voltage alarm (lower limit) occurred on lithium battery.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power
cord. Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the lithium battery mounted on base board.
If the same error persists, contact your service representative.
FP Temp Alm 09
A high temperature alarm occurred in front panel.
FP Temp Alm 02
A low temperature alarm occurred in front panel.
BB Temp Alm 09
A high temperature alarm occurred in base board.
BB Temp Alm 02
A low temperature alarm occurred in base board.
Check if fans in the server work normally.
If the same error persists, contact your service representative.
SASBP Temp C Alm
A temperature alarm occurred in SAS riser board.
Содержание Express5800/140Rf-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 20: ...x This page is intentionally left blank ...
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 235: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 264: ...7 18 Maintenance This page is intentionally left blank ...
Страница 397: ...9 64 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 413: ...C 4 This page is intentionally left blank ...
Страница 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...