Troubleshooting 8-17
Error
code
Error message
Recommended Action
0B70
The error occurred during temperature sensor
reading.
Contact your service representative.
0B71
System Temperature out of the range.
A fan failure or fan clogging may occur.
Contact your service representative to
request the maintenance.
0B74
The error occurred during voltage sensor
reading.
Contact your service representative.
0B75
System voltage out of the range.
0B78
The error occurred during fan sensor reading
0B7C
The error occurred during redundant power
module confirmation
Contact you service representative to
replace the power supply unit.
0B7D
The normal operation can't be guaranteed
with use of only one PSU
Contact you service representative to add
an additional power supply unit or replace
the existing power supply unit.
0B7E Mismatch
AC
Voltage
detected.
Check if the same voltage (100 or 200 VAC)
is input to power supply units.
Check installation status of power supply
units.
If the error cannot be corrected, contact
your service representative.
0B7F
Insufficient Power Supply Unit Configuration
Check installation status of power supply
units.
If the error cannot be corrected, contact
your service representative.
0B80 BMC
Memory
Test
Failed.
Turn off the power once and then on again
to start the server. If the error cannot be
corrected, contact your service
representative.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A
BMC SEL area full.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
0B8D
Could not redirect the console - BMC Busy -
0B8E
Could not redirect the console - BMC Error -
0B8F
Could not redirect the console - BMC
Parameter Error -
0B90
BMC Platform Information Area corrupted.
0B91
BMC update firmware corrupted.
0B92
Internal Use Area of BMC FRU corrupted.
All the commands and functions other than
the FRU command and the EMP function
can be used. This is not a fatal error. Turn
off the power once and then on again to
restart the server. If the error cannot be
corrected, contact your service
representative.
0B93
BMC SDR Repository empty.
Turn off the power once and then on again
to restart the server. If the error cannot be
corrected, contact your service
representative.
Содержание Express5800/140Rf-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 20: ...x This page is intentionally left blank ...
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 235: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 264: ...7 18 Maintenance This page is intentionally left blank ...
Страница 397: ...9 64 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 413: ...C 4 This page is intentionally left blank ...
Страница 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...