Troubleshooting 8-33
When STATUS lamp is lighting in amber
On-screen
message
Description
Recommended action
Err Pause in POST
The system is waiting for key entry due to serious POST error. Or, POST is
terminated forcedly even the serious POST error has occurred.
1. See "POST Error Messages" described earlier to find the error contents
and actions to take for the displayed message.
2. Reboot (reset) the server.
3. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Hang in POST
The system hangs up during POST.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
BIOS Recovery run
A fatal error occurred on system BIOS ROM.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Mem(xx) D(y) Unc
Err
An uncorrectable error occurred on DIMM in the following location.
(xx): Memory board that contains the failed DIMM.
AB: Memory board A or B
CD: Memory board C or D
(y):
Slot number of the memory board that contains the
failed DIMM.
1. Reboot (reset) the server.
2. Check installation status of the failed DIMM.
3. Replace the failed DIMMs.
If the same error persists, contact your service representative.
PCI Slot(x) Unc Err
An uncorrectable error occurred on PCI card installed in PCI slot (x).
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
3. Check installation status of the failed PCI card.
4. Replace the failed PCI card.
If the same error persists, contact your service representative.
PCIE Unc Err(x)
An uncorrectable error occurred on PCI Express bus.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Chipset Unc Err(x)
An uncorrectable error occurred on chipset.
1. Reboot (reset) the server.
2. Turn off the DC power of the server, and disconnect the AC power cord.
Then, connect the AC power cord again, and reboot the server.
If the same error persists, contact your service representative.
Содержание Express5800/140Rf-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 20: ...x This page is intentionally left blank ...
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 235: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 264: ...7 18 Maintenance This page is intentionally left blank ...
Страница 397: ...9 64 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 413: ...C 4 This page is intentionally left blank ...
Страница 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...