Troubleshooting 8-19
Error
code
Error message
Recommended Action
8150
NVRAM Cleared By Jumper.
Turn off the power. Then recover the
jumper setting to the original setting.
8151
Password Cleared By Jumper.
8160
Mismatch Processor Speed detected on
Processor 1.
Check the frequency of the processor. If it
is unknown, contact your service
representative.
8161
Mismatch Processor Speed detected on
Processor 2.
8162
Mismatch Processor Speed detected on
Processor 3.
8163
Mismatch Processor Speed detected on
Processor 4.
8170
Processor 1 not operating at intended frequency
8171
Processor 2 not operating at intended frequency
8172
Processor 3 not operating at intended frequency
8173
Processor 4 not operating at intended frequency
817F
All processors not operating at intended
frequency
81A0
Cache Cautionary status detected on Processor
1.
This is not a fatal error. Turn off the power
once and then on again to restart the
server. If the error cannot be corrected,
contact your service representative.
81A1
Cache Cautionary status detected on Processor
2.
81A2
Cache Cautionary status detected on Processor
3.
81A3
Cache Cautionary status detected on Processor
4.
8200
Online Spare Memory was not ready.
DIMM type mismatch is detected when the
online spare memory feature is enabled.
Contact your service representative.
8201
Mirroring Memory was not ready.
DIMM type mismatch is detected or
unnecessary installation in group #2 is
detected when the memory mirroring
feature is enabled. Check the DIMM type
or installation. If the error cannot be
corrected, contact your service
representative.
Содержание Express5800/140Rf-4
Страница 7: ......
Страница 8: ......
Страница 9: ......
Страница 20: ...x This page is intentionally left blank ...
Страница 152: ...4 54 Configuring Your Server The detailed settings is continued to the next page Click Next to view more information ...
Страница 163: ...Configuring Your Server 4 65 Use this menu to define several physical drives PD as a disk group DG ...
Страница 186: ...4 88 Configuring Your Server 3 Setting menu for VD 0 is displayed ...
Страница 194: ...4 96 Configuring Your Server This page is intentionally left blank ...
Страница 226: ...5 32 Installing the Operating System with Express Setup This page is intentionally left blank ...
Страница 235: ...Installing and Using Utilities 6 9 4 Click Parameter File Creator Parameter File Creator will appear ...
Страница 264: ...7 18 Maintenance This page is intentionally left blank ...
Страница 397: ...9 64 Upgrading Your Server 6 Remove the CPU protect cover 7 Remove the dummy cover from the socket ...
Страница 413: ...C 4 This page is intentionally left blank ...
Страница 457: ...E 22 Installing Windows Server 2003 This page is intentionally left blank ...