Configuring Your Server 4-27
RAID CONFIGURATION
This section describes how to use the internal hard disk drives in the disk array RAID configuration.
To use an external hard disk drive in a disk array, the optional disk array controller and the
additional disk drive are necessary. Refer to the manual of the optional disk array controller or
additional external disk drive for details.
For SAS-DAC model, refer to the N8103-91 Disk Array Controller (Internal SAS HDD) User's
Guide.
To configure the internal hard disk drives as the disk array drive:
Configure the six SCSI hard disk drives by using the onboard RAID controller.
Configure the hard disk drives by using the optional disk array controller.
RAID Configuration of SCSI Hard Disk Drive
You can configure a disk array (RAID0, RAID1, or RAID10) by using the onboard RAID controller
of the server.
You need six SCSI hard disk drives for configuration.
RAID0 (striping)
Stores data on two, three, or four hard disk drives by dividing it (striping). All the hard
disk drives can be accessed at the same time. This improves disk access performance
compared with using a single hard disk drive.
IMPORTANT:
RAID0 does not have data redundancy. When a hard disk drive
failure occurs, data cannot be restored.
Logical capacity of the array becomes a multiple of the connected
hard disk drive.
RAID1 (mirroring)
Stores the data being saved to one hard disk dive to another hard disk drive. This method
is called "mirroring." When storing data onto one hard disk drive, the same data is
simultaneously stored onto another hard disk drive. When a hard disk drive becomes
faulty, the one with the same data can be used. This provides operation without the system
going down.
IMPORTANT:
RAID1 reads or writes data to/from the several hard disk drives at
the same time. The disk access performance is lower than the single
disk.
Logical capacity of the array is equal to one hard disk drive
connected.
Содержание Express5800/120Rh-2
Страница 142: ...4 46 Configuring Your Server This page is intentionally left blank ...
Страница 236: ...7 12 Maintenance This page is intentionally left blank ...
Страница 320: ...9 46 Upgrading Your Server Pin Red Pin Red N8103 80F N8103 81F ...
Страница 336: ...9 62 Upgrading Your Server This page is intentionally left blank ...
Страница 338: ...A 2 Specifications This page is intentionally left blank ...
Страница 346: ...C 2 IRQ This page is intentionally left blank ...
Страница 406: ...G 4 Product Configuration Record Table This page is intentionally left blank ...