6. System Diagnostic Tool
Scalable Modular Server DX2000 Maintenance Guide
66
Chapter 1 Maintenance
(3)
Changing the test time of the diagnostic tool
When you execute the diagnostic tool (TeDoLi) on the system diagnostic management tool, the test time is set
to 8 minutes by default. If you want to change the execution time, change the following configuration file.
The setting time range is 1 to 9999 [min.].
1.
On the system diagnostic management tool, select [Applications], [System tools] and [Terminal] on
the top of the screen to start a terminal.
2.
Open the configuration file by using the following command.
3.
Change the setting as shown below.
(4)
Network testing with the diagnostic tool
This section describes how to test a network with the system diagnostic management tool. Network test is
disabled by default. Change the following configuration file.
1.
On the system diagnostic management tool, select [Applications], [System tools] and [Terminal] on
the top of the screen to start a terminal.
2.
Open the configuration file by using the following command.
3.
Change the setting as shown below.
[root@TD ~]# vi-N /var/lib/tftpboot/tedoli.conf
select all
desel LOM-PORT
:
time 8
* Change this value. For example, set “30” to set 30 minutes.
exec
[root@TD ~]# vi-N /var/lib/tftpboot/tedoli.conf
select all
desel LOM-PORT
* Delete this line.
desel ETH-PORT
* Delete this line.
param –s all LOM-PORT eec
param –s all ETH-PORT eec
outcmd "ethtool -A eth2 rx on tx on"
outcmd "ethtool -A eth3 rx on tx on"
time 8
exec