6. System Diagnostic Tool
Scalable Modular Server DX2000 Maintenance Guide
42
Chapter 1 Maintenance
| Num|*| Device List | Type |Prev| Status |
+----+-+---------------------------------+----------------+----+-------------+
| 1|*| MEMORY |MEMORY | |running |
| 2|*| CPU |CPU | |running |
| 3|!|-SATA |SATA | | |
| 4|*| HDD Slot0(TOSHIBA THNSNJ256G8NU|HDD-INT | |running |
| 5|!|-NIC |NIC | | |
| 6|*| Port1(eth0) |LOM-PORT | | |
| 7|*| Port2(eth1) |LOM-PORT | | |
| 8|*| SENSOR(TEMPERATURE) |TEMPERATURE | |running |
| 9|*| SENSOR(VOLTAGE) |VOLTAGE | |running |
| 10|*| LED |LED | | |
+----+-+---------------------------------+----------------+----+-------------+
The test will terminate in 9 minutes.
Screen image:
Description
number
Description
(a)
Display the status of CSC modules and server modules.
Module List
: Indicates the server module number (loaded position).
CSC
: Indicates CSC modules.
CPU Board : Indicates server modules.
Power
ON
: Indicates DC ON status.
OFF
: Indicates DC OFF status.
Type
: Indicates the tool type.
(blank)
: Indicates that the tool is not started.
TP
: Indicates the diagnosis module of CSC.
MNG PC
: Indicates the system diagnostic management tool.
TeDoLi
: Indicates the diagnostic tool (TeDoLi).
Status
: Indicates the diagnostic status of the server module.
(
blank)
: Indicates no execution.
Run
: Indicates that diagnosis is running.
PASS
: Indicates that diagnosis normally ended.
FAIL
: Indicates that the result of diagnosis is abnormal.
ABRT
: Indicates that diagnosis abnormally ended.
WARN
: Indicates that the result of diagnosis includes warning.
Содержание DX2000
Страница 131: ... MEMO ...